Skip to content
MaestroHub
Menu
Free trialdownload and run it todayStart the pilot

Integrations

OPC UA to AWS IoT SiteWise, without a script.

Read the OPC UA nodes with MaestroHub, give each value a governed name and unit, and send them to SiteWise asset properties in batches. MaestroHub can create the asset models and assets automatically from property aliases, and buffers writes when the link drops.

The flow

One value, from the machine to AWS IoT SiteWise. Illustrative.

OPC UAindustrial protocolns=2;s=Comp2.Pressure
MaestroHub

Compressor 2 pressure · 6.8 bar · Good

  • named, unit, quality
  • origin stamped
  • buffered on disk
AWS IoT SiteWiseindustrial cloud service/plant/line2/compressor2/pressure

Why do it with MaestroHub

More than a pipe from OPC UA to AWS IoT SiteWise.

01

Assets created for you

Zero-touch auto-modelling builds SiteWise models and assets from the aliases, instead of clicking them together.

02

Not tied to one cloud

The same values can go to SiteWise and to a warehouse or broker outside AWS, each with its own buffer.

03

Quality passes through

SiteWise receives each value's quality and timestamp as MaestroHub verified them.

What lands in AWS IoT SiteWise

An example. You choose the fields in the pipeline.

aliasvaluequalitytimestamp
/plant/line2/compressor2/pressure6.8GOOD2026-10-03T06:00:01Z

Set it up in three steps

  1. 1

    Connect OPC UA

    Add the OPC UA server, browse its address space and pick the nodes, or add hundreds at once with bulk creation.

  2. 2

    Give the values meaning

    Map each value to a topic in the namespace with its name, unit and schema. Quality and origin are stamped on every value.

  3. 3

    Deliver to AWS IoT SiteWise

    Add a SiteWise output; assets and models can be created automatically from the property aliases you send.

Before you start

What each side needs, from the connector documentation.

OPC UA

  • The server address, built as opc.tcp://host:port/path. The standard OPC UA port is 4840.
  • For any Security Policy other than None, a client certificate: paste your own (RSA keys only) or let MaestroHub generate a self-signed one.
  • If you use the auto-generated certificate, the OPC UA server administrator must trust it on the server.
  • A username and password when the server does not allow Anonymous access.

Example settings

Server Hostname
opcua.example.com
Port
4840
Security Policy
Basic256Sha256
Security Mode
SignAndEncrypt
Certificate Mode
Auto-generate (self-signed)
Authentication Type
UsernamePassword
OPC UA connector documentation

AWS IoT SiteWise

  • The AWS region of your SiteWise resources. Custom regions such as us-gov-west-1 can be entered.
  • AWS credentials: an access key ID and secret access key together, or both left empty to use IAM roles and the default credential chain (recommended on EC2, ECS and EKS).
  • For SiteWise Edge or a VPC endpoint: the endpoint URL for the Custom Endpoint field.

Example settings

Region
us-east-1
Default Batch Size
10
Property Alias (Write)
/factory/motor-001
Data (Write)
{"temperature": ((temp)), "rpm": ((speed))}
Quality (Write)
GOOD
Schema Hints (Write)
{"temperature": "DOUBLE"}
AWS IoT SiteWise connector documentation

Things to know

Pitfalls and limits the documentation calls out, so they don't surprise you on site.

OPC UA

  • Security Policy and Security Mode must agree. Policy None requires Mode None. Any other policy requires Sign or SignAndEncrypt.
  • Node identifiers need a namespace index and a type prefix (i=, s=, g=, b=). Namespace 0 is typically standard nodes, 2 and up custom nodes. Browse a small scope first to find the exact IDs.
  • On Monitor functions, set the sampling interval equal to or faster than the publishing interval, or changes can be missed. Subscriptions are recreated automatically after a lost connection or a session timeout.

Limits

  • Manual client certificates support RSA keys only. Auto-generated certificates are RSA 2048-bit and valid for 365 days.
  • Monitor functions cannot be created through Quick Add. Use the full Function Builder.

AWS IoT SiteWise

  • Store & Forward is off by default. Until you turn it on for the connection under Orchestrate, Store & Forward, a failed write is not buffered or retried.
  • Whole numbers are inferred as INTEGER, so a temperature of 25 becomes INTEGER. Use Schema Hints such as {"temperature": "DOUBLE"} to force the type.
  • Auto-Create Model & Asset is meant for prototyping. In production, pre-create models and assets and use explicit property aliases.

Limits

  • AWS accepts at most 10 entries per BatchPutAssetPropertyValue call. The connector splits larger payloads into chunks.

What teams use it for

SiteWise dashboards and alarms

Live asset views for operations teams in AWS.

Fleet monitoring

The same asset structure across plants and lines.

Feeding AWS analytics

SiteWise data onward to S3, Athena or SageMaker.

Ways to connect OPC UA to AWS IoT SiteWise

In general terms. Check any specific product for its own details.

Compare a custom script, a flow tool, a cloud vendor's edge service and MaestroHub

Swipe sideways to see every column

A custom scriptA flow toolA cloud vendor's edge serviceMaestroHub
Talks OPC UAA library you chooseCommunity plug-insDepends on the vendorBuilt in, one of 90+ connectors
Names, units and schemaYou write itYou build itPartly, in the vendor's modelOne governed namespace
Quality on every valueYou write itYou build itDepends on the vendorBuilt in, carried through calculations
Where each value came fromYou write itYou build itDepends on the vendorStamped on every value
Survives a network outageYou build itYou build itUsually, to that vendor's cloudOn disk, per destination, in order
Several destinations at onceOne script eachYes, flow by flowMostly that vendor's cloudAny mix, each with its own buffer
Permissions and auditYou build itYou build itCloud account permissionsRoles, single sign-on, audit trail
AI agents can use the dataYou build itYou build itDepends on the vendorThrough the MCP server

Questions

How do I connect OPC UA data to AWS IoT SiteWise?

Read the OPC UA nodes with MaestroHub, give each value a governed name and unit, and send them to SiteWise asset properties in batches. MaestroHub can create the asset models and assets automatically from property aliases, and buffers writes when the link drops.

Do I need to write code to connect OPC UA to AWS IoT SiteWise?

No. You configure the OPC UA connection and the AWS IoT SiteWise output in MaestroHub and join them with a pipeline. Transformations can be added where you need them.

Where does MaestroHub run for this?

On your own infrastructure next to the machines: an edge box, a virtual machine or Kubernetes. Nothing has to leave your network.

Why not just write a script for OPC UA to AWS IoT SiteWise?

A script works on day one. The cost comes later: decoding and naming values, handling bad quality, buffering through outages, keeping credentials safe, and doing it again for the next machine and the next destination. MaestroHub does those once, for every connector.

What else can OPC UA data go to?

More than 90 connectors are included in every edition, among them historians, databases, cloud warehouses, message brokers and business systems, so the same values can feed several destinations at once.

Try OPC UA to AWS IoT SiteWise yourself.

The free trial includes every connector. No factory to hand? The Digital Factory Simulator serves OPC UA, Modbus, MQTT and more on your laptop.

Cookie preferences