Integrations
OPC UA to AWS IoT SiteWise, without a script.
Read the OPC UA nodes with MaestroHub, give each value a governed name and unit, and send them to SiteWise asset properties in batches. MaestroHub can create the asset models and assets automatically from property aliases, and buffers writes when the link drops.
The flow
One value, from the machine to AWS IoT SiteWise. Illustrative.
OPC UAindustrial protocolns=2;s=Comp2.Pressure
MaestroHubCompressor 2 pressure · 6.8 bar · Good
- named, unit, quality
- origin stamped
- buffered on disk
AWS IoT SiteWiseindustrial cloud service/plant/line2/compressor2/pressureWhy do it with MaestroHub
More than a pipe from OPC UA to AWS IoT SiteWise.
Assets created for you
Zero-touch auto-modelling builds SiteWise models and assets from the aliases, instead of clicking them together.
Not tied to one cloud
The same values can go to SiteWise and to a warehouse or broker outside AWS, each with its own buffer.
Quality passes through
SiteWise receives each value's quality and timestamp as MaestroHub verified them.
What lands in AWS IoT SiteWise
An example. You choose the fields in the pipeline.
| alias | value | quality | timestamp |
|---|---|---|---|
| /plant/line2/compressor2/pressure | 6.8 | GOOD | 2026-10-03T06:00:01Z |
Set it up in three steps
- 1
Connect OPC UA
Add the OPC UA server, browse its address space and pick the nodes, or add hundreds at once with bulk creation.
- 2
Give the values meaning
Map each value to a topic in the namespace with its name, unit and schema. Quality and origin are stamped on every value.
- 3
Deliver to AWS IoT SiteWise
Add a SiteWise output; assets and models can be created automatically from the property aliases you send.
Before you start
What each side needs, from the connector documentation.
OPC UA
- The server address, built as opc.tcp://host:port/path. The standard OPC UA port is 4840.
- For any Security Policy other than None, a client certificate: paste your own (RSA keys only) or let MaestroHub generate a self-signed one.
- If you use the auto-generated certificate, the OPC UA server administrator must trust it on the server.
- A username and password when the server does not allow Anonymous access.
Example settings
- Server Hostname
- opcua.example.com
- Port
- 4840
- Security Policy
- Basic256Sha256
- Security Mode
- SignAndEncrypt
- Certificate Mode
- Auto-generate (self-signed)
- Authentication Type
- UsernamePassword
AWS IoT SiteWise
- The AWS region of your SiteWise resources. Custom regions such as us-gov-west-1 can be entered.
- AWS credentials: an access key ID and secret access key together, or both left empty to use IAM roles and the default credential chain (recommended on EC2, ECS and EKS).
- For SiteWise Edge or a VPC endpoint: the endpoint URL for the Custom Endpoint field.
Example settings
- Region
- us-east-1
- Default Batch Size
- 10
- Property Alias (Write)
- /factory/motor-001
- Data (Write)
- {"temperature": ((temp)), "rpm": ((speed))}
- Quality (Write)
- GOOD
- Schema Hints (Write)
- {"temperature": "DOUBLE"}
Things to know
Pitfalls and limits the documentation calls out, so they don't surprise you on site.
OPC UA
- Security Policy and Security Mode must agree. Policy None requires Mode None. Any other policy requires Sign or SignAndEncrypt.
- Node identifiers need a namespace index and a type prefix (i=, s=, g=, b=). Namespace 0 is typically standard nodes, 2 and up custom nodes. Browse a small scope first to find the exact IDs.
- On Monitor functions, set the sampling interval equal to or faster than the publishing interval, or changes can be missed. Subscriptions are recreated automatically after a lost connection or a session timeout.
Limits
- Manual client certificates support RSA keys only. Auto-generated certificates are RSA 2048-bit and valid for 365 days.
- Monitor functions cannot be created through Quick Add. Use the full Function Builder.
AWS IoT SiteWise
- Store & Forward is off by default. Until you turn it on for the connection under Orchestrate, Store & Forward, a failed write is not buffered or retried.
- Whole numbers are inferred as INTEGER, so a temperature of 25 becomes INTEGER. Use Schema Hints such as {"temperature": "DOUBLE"} to force the type.
- Auto-Create Model & Asset is meant for prototyping. In production, pre-create models and assets and use explicit property aliases.
Limits
- AWS accepts at most 10 entries per BatchPutAssetPropertyValue call. The connector splits larger payloads into chunks.
What teams use it for
SiteWise dashboards and alarms
Live asset views for operations teams in AWS.
Fleet monitoring
The same asset structure across plants and lines.
Feeding AWS analytics
SiteWise data onward to S3, Athena or SageMaker.
Ways to connect OPC UA to AWS IoT SiteWise
In general terms. Check any specific product for its own details.
Compare a custom script, a flow tool, a cloud vendor's edge service and MaestroHub
Swipe sideways to see every column
| A custom script | A flow tool | A cloud vendor's edge service | MaestroHub | |
|---|---|---|---|---|
| Talks OPC UA | A library you choose | Community plug-ins | Depends on the vendor | Built in, one of 90+ connectors |
| Names, units and schema | You write it | You build it | Partly, in the vendor's model | One governed namespace |
| Quality on every value | You write it | You build it | Depends on the vendor | Built in, carried through calculations |
| Where each value came from | You write it | You build it | Depends on the vendor | Stamped on every value |
| Survives a network outage | You build it | You build it | Usually, to that vendor's cloud | On disk, per destination, in order |
| Several destinations at once | One script each | Yes, flow by flow | Mostly that vendor's cloud | Any mix, each with its own buffer |
| Permissions and audit | You build it | You build it | Cloud account permissions | Roles, single sign-on, audit trail |
| AI agents can use the data | You build it | You build it | Depends on the vendor | Through the MCP server |
Questions
How do I connect OPC UA data to AWS IoT SiteWise?
Read the OPC UA nodes with MaestroHub, give each value a governed name and unit, and send them to SiteWise asset properties in batches. MaestroHub can create the asset models and assets automatically from property aliases, and buffers writes when the link drops.
Do I need to write code to connect OPC UA to AWS IoT SiteWise?
No. You configure the OPC UA connection and the AWS IoT SiteWise output in MaestroHub and join them with a pipeline. Transformations can be added where you need them.
Where does MaestroHub run for this?
On your own infrastructure next to the machines: an edge box, a virtual machine or Kubernetes. Nothing has to leave your network.
Why not just write a script for OPC UA to AWS IoT SiteWise?
A script works on day one. The cost comes later: decoding and naming values, handling bad quality, buffering through outages, keeping credentials safe, and doing it again for the next machine and the next destination. MaestroHub does those once, for every connector.
What else can OPC UA data go to?
More than 90 connectors are included in every edition, among them historians, databases, cloud warehouses, message brokers and business systems, so the same values can feed several destinations at once.
Try OPC UA to AWS IoT SiteWise yourself.
The free trial includes every connector. No factory to hand? The Digital Factory Simulator serves OPC UA, Modbus, MQTT and more on your laptop.